Illustration Component Test Results
Transformer
Discharge Capacitor
Remove all wires from terminals.
Measure resistance from:
230 to COM..................................................
208 to COM..................................................
230 to Ground..............................................
208 to Ground..............................................
Terminal 5 to 6.............................................
Terminal 4 to Ground...................................
Less than 1
Less than 1
Infinite
Infinite
Less than 1
Approximately
Convection blower
motor
Use Service test to verify operation
ST1-1 to ST1-3
BK BU
Convection heating
element (Top)
Disconnect wires from terminals.
Measure resistance across heating
element.
Element 2000 W .......................
Approximately 19 - 22
Heating
element (Bottom)
Disconnect wires from terminals.
Measure resistance across heating
element.
Element 3000 W .........................
Approximately 14
Resistance thermal
device (RTD)
Temperature
32°F
.............................................................
350°
...........................................................
Resistance
1000
1654
0 1
2 4
6 8
Relay (Power)
This relay contains a
diode in the coil
circuit.
Measure resistance from:
Terminal 0 to terminal 1 (coil) ...........
.
0 1
2 4
6
8
Approximately 6 to 7 M
NOTE: Analog meter is recommended
for measurement.
NOTE: If using a digital meter it must
contain a battery of 6 volts minimum.
Wire harness High voltage board
to display module
harness
Test continuity of wires ....................... Indicates continuity
----------------------------------------------
Line Voltage
ST2
GN - YL - OR -BU-------------------------------
Disconnect ST2
Fan should operate at
High Speed
Primary switch
Secondary switch
Monitor Interlock
switch
Com
NO
NC
ST1
ST2
NC to Com
NO to Com
Indicates continuity
Indicates infinity
COM
NC
NO
NC to Com
NO to Com
Indicates continuity
Indicates infinity
31
2
1 to 2
1 to 3
Indicates continuity
Indicates infinity
(0°C)
(177°C)
46
7
6
2
8
3 1
5
4
9
10
Limiter
Note: Unit must have
power applied to test
Limiter.
Red - Orange Lead Terminals
Line Voltage
Yellow - Yellow Leads disconnected from
Limiter
24vdc across yellow leads
(Polarity must be correct)
Terminal 6 - Terminal 7
0
Indicates continuity
..
.......................
.
.......................
.......................
.......................
J2
GND
J1
Power supply board
-24 Volt
Red to White lead - J2 Power Supply Board
Approximately 24vdc
Component Testing Procedures